• Altima NEO@lemmy.zip
    link
    fedilink
    English
    arrow-up
    11
    ·
    edit-2
    1 year ago

    No expansion tank?

    Guessing its a hybrid unit? I have a hybrid one by GE. Goddamn its loud.

    Don’t forget to turn up the water temperature. Mine also was set to 120 by default, but that’s too cold. You need 135-140 or so, otherwise you’ll find that you run out of hot water pretty quickly, especially if you have people taking showers back to back, or running the dishwasher/washer while someones showering, etc.

    • Another Person @lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      10
      ·
      edit-2
      1 year ago

      What’s an expansion tank? I set it up like the old one was set up. All I did was disconnect the old one and reconnect the new one to the same pipes coming out of the wall.

      • rockSlayer@lemmy.world
        link
        fedilink
        arrow-up
        7
        arrow-down
        3
        ·
        edit-2
        1 year ago

        An expansion tank is necessary for water heaters, because the process of heating water causes it to expand. Without an expansion tank, pressure could build to unsafe levels

        • SpeakinTelnet@sh.itjust.works
          link
          fedilink
          arrow-up
          17
          ·
          1 year ago

          All tanks are equipped with a safety release for the pressure and the only time when that delta in pressure can be problematic is when you go from completely cold to hot due to the higher amount of water that can fit in the tank at lower temp.

          Otherwise I’ve never seen a house in Canada with an extension tank attached to the water heater and the water come in ice cold in the winter.

        • falsem@kbin.social
          link
          fedilink
          arrow-up
          11
          ·
          1 year ago

          Pressure won’t build up, it will be let out by the pressure relief valve and make a mess on the floor. Which is also undesirable.

          • SheeEttin@lemmy.world
            link
            fedilink
            English
            arrow-up
            2
            arrow-down
            1
            ·
            1 year ago

            Well, right up until the pressure relief valve fails. Whether it fails open or closed, you’re gonna have a bad time, because either way you’re probably going to have a lot of water where there’s not supposed to be water.

          • nowwhatnapster@lemmy.world
            link
            fedilink
            arrow-up
            3
            ·
            1 year ago

            If you are on municipal water and there is no check valve between you and the water meter then the municipal water supply is acting as the expansion tank. It may not be to code in your area but that’s how many homes were built in the past.

          • Rixonomic@lemmy.world
            link
            fedilink
            arrow-up
            1
            ·
            15 days ago

            The expansion tank isn’t just for the water heater. That increased pressure puts undue strain on the entire plumbing system in your home. It will cause toilet fill valves to fail, supply lines to rupture, and possibly even pinhole leaks. A lot of plumbing issues are solved by installing an expansion tank.

          • rockSlayer@lemmy.world
            link
            fedilink
            arrow-up
            1
            ·
            1 year ago

            Honestly, I don’t know, I’m not a plumber. There are a couple possibilities, including that it was built into the water heater or the relief valve did it’s thing. Some water heaters don’t need expansion tanks at all, either. It’s generally a “just in case” thing, since the right failures in the wrong way could lead to a hot water bomb going off in your house.

        • Another Person @lemmy.worldOP
          link
          fedilink
          English
          arrow-up
          3
          ·
          edit-2
          1 year ago

          In reading it looks like it is for homes newer than 1986? Our old water heater was 20 years old and we never had any issues with the pressure getting too high.

    • deadsenator@lemmy.ca
      link
      fedilink
      English
      arrow-up
      1
      ·
      1 year ago

      Another comment here says the lower element of this unit has a flaw. Might look into that.